IO-Link Master 8-EIP
This IO-Link Master features an IP67 housing with eight M12 IO-Link ports and T-Coded power connectors for harsh environments. This industrial IO-Link gateway has a wide operating temperature from -25° to 60°C.
Part Number: 99608-8
New model available at 99609-5 with L-Coded power
- Eight M12 IO-Link ports to EtherNet/IP™, which allows up to eight sensor or actuator connections on a single master
- T-Coded power connectors
- Rugged IP67 housing design for harsh environments
- Dual Ethernet ports
- Additional digital input on every port
- Power port sharing capability
- MultiLink™ – Simultaneously provides IO-Link device access to multiple controllers
- EtherNet/IP™ Class 1 (Implicit) and Class 3 (Explicit) interfaces
- EtherNet/IP™ and Modbus TCP access to IO-Link process, event, and service data
- HMI, SCADA, and PLC access to IO-Link ISDU blocks without complex programming
- EDS files and sample programs
- Convenient EtherNet/IP Write-to-Tag/File, Read-from-Tag/File data exchange option
- Supports OPC UA
- Powerful web GUI for configuration and diagnostics, including: IO-Link device management using the IO-Link device manufacturers IODD file for easy device configuration, Automatic data storage (upload and download), Manual data storage (upload and download), Device validation, and Data validation.
- Works with PortVision DX - a discovery management application
- LEDs for device, network, and port status
- Wide operating temperature (-40° to +70°C)
- IO-Link V1.0 and V1.1 compatibility
- IO-Link COM1, COM2 and COM3 (230K baud rate) support
IO-Link Master common configuration networking diagram
Comtrol’s IO-Link Master combines the benefits of the IO-Link standard with the EtherNet/IP™ and Modbus TCP protocols. The IO-Link Master effectively shields the PLC programmers from the IO-Link complexities by handling those complexities itself. The result is simplified EtherNet/IP™ and Modbus TCP interfaces, which decreases system development time and installation efforts.
This IO-Link Master features a rugged IP67 slim-line design incorporating two Fast Ethernet ports, eight M12 IO-Link ports with T-Code power connectors. Designed for harsh environments, its machine-mount design uses industrial grade components. The IO-Link Master is easily integrated into a system network and is compatible with existing and new industrial Ethernet installations.
- IO-Link Master 8-EIP
- Quick Start card
- Network Interface 10/100BASE-TX
- EnclosureMolded Polyamide 66 (potted)
- Ingress Protection Rating IP67
- Installation and Grounding MethodMachine or panel mount
Two-hole M4 or #8 screws - Network ProtocolsEtherNet/IP™, Modbus/TCP (slave)
- Connectors (M12)8 - IO-Link
2 - Ethernet
2 - Power - LED IndicatorsPower, Module Status, Network Status, IO-Link, DI and Ethernet Port Status
- Dimensions 8.35" x 2.56" x 1.18"
212 x 65 x 30 mm - Product Weight1.0 lb
454g
- Power Connectors1 x Power Input
1 x Power Output - Connector typeM12, T-coded, 4-position
- Power Connector Pin-OutPin 1 – US+ (Master electronics & sensor supply)
Pin 2 – UA- (Actuator supply)
Pin 3 – US- (Master electronics & sensor supply)
Pin 4 – UA- (Actuator supply) - DC Input Voltage Range 20 VDC – 30 VDC
- Power Supply In
- Module electronics and sensor (Us)12A (max.)
- Actuator supply (UA)12A (max.)
- Power Consumption (module electronics)100mA @ 24VDC
- Power Supply Out
- US12A (max.) *
- UA12A (max.) **
- * US output available is determined by subtracting the following from the available input current:• Module electronics
• Total C/Q current for all IO-Link ports
• Total sensor supply current - ** UA output available is the same as the available UA input current
- Operating Temperature-25°C to +60°C
- Storage Temperature-40°C to +70°C
- Operating Humidity (Non-Condensing)10% to 95%
- Storage Humidity (Non-Condensing)10% to 95%
- Ingress Protection IP67 (EN / IEC 60529)
- Shock / Vibrations EN60068-2-6
EN60068-2-27 - Environmental / Mechanical ApprovalsIEC 61131-2
- Number of Ports2
- Connector TypeM12 D-coded, 4-pin
- Ethernet Specification 10/100BASE-TX
- StandardsIEEE 802.3: 10BASE-T
IEEE 802.3u: 100BASE-TX - Auto-MD/MDI-XYes
- Auto-NegotiationYes
- Link Distance100 m
- Cable TypesUnshielded or Shielded twisted pair
- IPv4 AddressingYes
- IO-Link VersionSupports V1.0 and V1.1
- Connectors8 (PORT 1 – 8)
- Connector typeM12, A-coded Female, 5-position
- Channels8 x IO-Link / Digital I/O (configurable)
8 x DI - Port PinoutPin 1 – L+
Pin 2 – L-
Pin 3 – DI
Pin 4 – C/Q (configurable) -
Configurations per Port
- Pin 4 (configurable):IO-Link
DI (SIO mode)
DO (SIO mode) - Pin 3: DI
- Pin 4 (configurable):IO-Link
- Output Current L+/L- (sensor)1.6 A (Port 1)
500 mA (Port 2 – 8; each) - Output Current C/Q (Pin 4)200 mA
- Output Current per Master (C/Q & L+/L-) 6.7 A (max.)
- IO-Link Mode Transfer Rates4.8K (COM1)
38.4K (COM2)
230.4K (COM3) - Baud Rate RecognitionAutomatic
- Cable Length20 m (max.)
- ProtectionOverload and short circuit protection (Self recovers)
- Cable Length (Maximum)20 m
- Input CharacteristicsIEC 61131-2 Type 1 and Type 3 Compliant
- Input ThresholdHigh: 10.5 – 13.0V
Low: 8.0 – 11.5V - Typical Input Current3 mA
- Cable length (max.)30 m
- Typical Output Voltage 24 VDC
- Output Current (max.)200 mA
- Output Current per Master1.6 A (max.)
- Lamp Load (max.)4W
- ProtectionOverload and short circuit protection
- Output FunctionPNP/NPN (Push-Pull)
- Cable length (maximum)30 m
- Input CharacteristicsIEC 61131-2 Type 1 and Type 3 Compliant
- Typical Input Current3 mA
- Input ThresholdHigh: 6.8 – 8.0V< br/>Low: 5.2 – 6.4V
- Reverse Polarity ProtectedYes (-40V to +40V)
- Cable length (maximum)30 m
- Supported PLCs
- Including but not limited to:Control Logix
Compact Logix
RSLogix
SLC 500
PLC5
MicroLogix - Other Class 1 or Class 3 EtherNet/IP PLCs may be supported
- Including but not limited to:Control Logix
- ISDU Read & WritesUp to 40 individual commands in one EtherNet/IP message
- ISDU CommandsSelectable byte swapping (none, 16-bit, or 32-bit)
Selectable payload sizes (4 to 232 bytes)
ISDU block index
ISDU sub-index
Length of read or write
Data payload - Web Page Configuration
- Provides the following capabilities:Port configuration for ISDU Data, Process Data, Transfer Mode, Read/Write, Write PDI to Tag/File, and Read PDO from Tag/File.
EtherNet/IP configuration:
• Time to Live (TTL) Network Value
• Multicast IP Address Allocation Control
• User-Defined Number of Multicast IP Addresses
• User-Defined Multicast Starting IP Address - Session Encapsulation Timeout
- Provides the following capabilities:Port configuration for ISDU Data, Process Data, Transfer Mode, Read/Write, Write PDI to Tag/File, and Read PDO from Tag/File.
- DiagnosticsYes
- Electronic Data Sheet (EDS)Yes
- Sample PLC ProgramsYes
- ConfigurationEmbedded web interface, IO-Link, EtherNet/IP, and Modbus TCP
- Data StorageAutomatic or Manual - Upload and/or Download
- Device Validation Yes
- Data ValidationYes
- DiagnosticsIO-Link, EtherNet/IP, and Modbus TCP
- Powerful Web InterfaceProvides the following capabilities:
• Firmware upgradable
• Password protected with Admin, Operator, and User accounts
• ISDU batch handling
• Load IODD files to configure the IO-Link device
• IODD Handler parses xml files making them readable and configurable
• Log files - Upgradable Firmware Yes (Web page or using PortVision DX)
- Remote ParameterizationYes
- Mobile App SupportSimplify monitoring of control system Process and Service Data using simple standard clients available for free in Google Play and Apple App Store
- Packaged Shipping Weight1.2 lb
544.3 g - Package Dimensions (L x W x H)10.5" x 4.5" x 1.5"
267 x 114 x 38mm - UPC Code7-56727-99608-8
- Country of OriginUSA
- ECCN5A992
- Schedule B Number8517.62.0050
- ImmunityEuropean Standard EN 61000-6-2
International Standard IEC 61000-6-2- EN/IEC 61131-2 and EN/IEC 61131-9IEC 1000-4-2/EN 61000-4-2: Electrostatic Discharge (ESD)
IEC 1000-4-3/EN 61000-4-3: Radiated, Radio-Frequency (RF)
IEC 1000-4-4/EN 61000-4-4: Fast Transient/Burst
IEC 1000-4-5/EN 61000-4-5: Surge
IEC 1000-4-6/EN 61000-4-6: Conducted disturbance
IEC 1000-4-8/EN 61000-4-8: Magnetic field
IEC 1000-4-11/EN 61000-4-11: Dips and Voltage Variations
- EN/IEC 61131-2 and EN/IEC 61131-9IEC 1000-4-2/EN 61000-4-2: Electrostatic Discharge (ESD)
- EmissionEuropean Standard EN 61000-6-4
International Standard IEC 61000-6-4
AS/NZS CISPR-11- FCC Part15 Subpart B Class A limit
- SafetyCSA C22.2 No. 61010-1-12 / CSA C22.2 No. 61010-1-201
UL 61010-1 / UL 61010-1-201
UL File # E360395 - VibrationEN 60068-2-6/ IEC 60068-2-6
- Mechanical ShockEN 60068-2-27/ IEC 60068-2-27
- Environmental / Mechanical Test ApprovalsIEC 61131-2
IEC 60529 - Ingress Protection RatingIngress Protection rating IP20 (IEC 60529)
- OtherThe components of this product comply with the requirements of the EMC/EMI Directive 2014/30/EU, Directive 2011/65/EU on the Restriction of the use of certain Hazardous Substances (RoHS2).
- Regulatory Approval Symbols
» Industrial Distributors
» North American Distributors
» International Distributors
Comtrol's Pre-sales Team
For sales questions or to locate a reseller near you.
+1-800-926-6876 (1-800-Go Rocket)
+1-763-957-6000
Fax: +1-763-957-6001
[email protected]
Comtrol's Industrial Automation Sales
For sales questions or to locate an industrial distributor near you.
+1-800-926-6876 (1-800-Go Rocket)
+1-763-957-6000
Fax: +1-763-957-6001
[email protected]
Call +1.763.957.6000, or e-mail [email protected]
For technical assistance, our U.S.-based technical support team is only a phone call away.
Call +1.763.957.6000, or submit your question online, or visit our forum .
File Name | Download |
---|---|
Documentation | ![]() |
Software | ![]() |
EDS Files | ![]() |