IO-Link Master DR-8-EIP-T

The IO-Link Master DR-8-EIP-T is an 8-Port IO-Link Master featuring EtherNet/IP™ communication, dual Ethernet ports, with pluggable/removable screw terminal connectors in a compact DIN rail design.

Part Number: 99675-0

PortVision DXweb IIoT

 
 


Pepperl+Fuchs Comtrol’s IO-Link Master combines the benefits of the IO-Link standard with the EtherNet/IP™ and Modbus TCP protocols. The IO-Link Master effectively shields the PLC programmers from the IO-Link complexities by handling those complexities itself. The result is simplified EtherNet/IP™ and Modbus TCP interfaces, which decreases system development time and installation efforts.

The IO-Link Master easily installs on a standard DIN rail and incorporates two Fast Ethernet ports, eight pluggable/removable screw terminal IO-Link ports. This product is designed with industrial grade components and redundant power inputs to make it exceptionally reliable for critical applications. The IO-Link Master is easily integrated into a system network and is compatible with existing and new industrial Ethernet environments.


Learn more about IO-Link

IO-Link Resources


Includes:
  • IO-Link Master DR-8-EIP-T
  • Quick Start card
 
Hardware
  • Network Interface10/100BASE-TX
  • EnclosurePolyamide, UL94V-0
  • Ingress Protection RatingIP20
  • Installation and Grounding MethodDIN Rail
  • Connectors (PWR & IO-Link)Pluggable screw terminal block plugs
  • Connection MethodScrew terminals
  • Connectors (Ethernet)RJ45
  • Network ProtocolsEtherNet/IP & Modbus TCP
  • Channels8 x IO-Link / Digital I/O (configurable)
    8 x Digital Input DI
    2 x Ethernet
  • LED Indicators Module Status, Network Status, IO-Link, DI, Ethernet Link & Activity
  • Dimensions (Width x Height x Depth) 1.78” x 4.25” x 4.5”
    45 mm x 108 mm x 114 mm
  • Product Weight 9.6 oz
    272 g
Electrical Specifications
  • DC Input Voltage Range18 VDC – 30 VDC
  • Current Consumption with sensors3.7 A max. at 24VDC
  • Current Consumption (system electronics)155 mA at 24VDC
  • Power Consumption (system electronics)3.75 W
  • Power Input Connector1
Environmental Specifications
  • Operating Temperature-40°C to +70°C
  • Storage Temperature-40°C to +85°C
  • Operating Humidity (Non-Condensing)10% to 95%
  • Storage Humidity (Non-Condensing)10% to 95%
  • Shock / VibrationsEN60068-2-6
    EN60068-2-27
  • Environmental / Mechanical ApprovalsIEC 61131-2
    IEC 60529
Ethernet Interface Specifications
  • Connector TypeRJ45
  • Number of Ports2
  • Ethernet Specification10/100BASE-TX
  • Standards IEEE 802.3: 10BASE-T
    IEEE 802.3u: 100BASE-TX
  • Auto-MD/MDI-XYes
  • Auto-NegotiationYes
  • Link Distance100 m
  • Cable TypesUnshielded or Shielded twisted pair
  • IPv4 AddressingYes
IO-Link Ports Specifications
  • Number of Connectors8 (PORT 1 – 8)
  • Number of Channels8 x IO-Link / Digital I/O (configurable)
    8 x DI
  • IO-Link VersionSupports V1.0 and V1.1
  • Port PinoutPin 1 – L+
    Pin 2 – L-
    Pin 3 – DI
    Pin 4 – C/Q (configurable)
  • Configurations per Port
    • Pin 4 (configurable):IO-Link
      DI (SIO mode)
      DO (SIO mode)
    • Pin 3: DI
  • Output Current L+/L- (Pins 1 & 2)200 mA
  • Output Current C/Q (Pin 4)200 mA
  • Output Current per Master 3.2 A (max.)
  • IO-Link Mode Transfer Rates4.8K (COM1)
    38.4K (COM2)
    230.4K (COM3)
  • Baud Rate RecognitionAutomatic
  • Cable Length20 m (max.)
IO-Link Ports – Digital Input SIO Mode (Port Pin 4)
  • Input CharacteristicsIEC 61131-2 Type 1 and Type 3 Compliant
  • Sensor supply current (L+/L-)200 mA
  • Sensor Supply current per Master1.6 A (max.)
  • Input ThresholdHigh: 10.5 – 13.0V
    Low: 8.0 – 11.5V
  • Cable length (max.)30 m
IO-Link Ports – Digital Output SIO Mode (Port Pin 4)
  • Typical Output Voltage 24 VDC
  • Output Current (max.)200 mA
  • Output Current per Master1.6 A (max.)
  • ProtectionOverload and short circuit protection
  • Output FunctionPNP/NPN (Push-Pull)
  • Cable length (maximum)30 m
IO-Link Ports – Digital Input (Port Pin 3; dedicated)
  • Input CharacteristicsIEC 61131-2 Type 1 and Type 3 Compliant
  • Typical Input Current3 mA
  • Input ThresholdHigh: 6.8 – 8.0V
    Low: 5.2 – 6.4V
  • Reverse Polarity ProtectedYes (-40V to +40V)
  • Cable length (maximum)30 m
EtherNet/IP Specifications
  • Supported PLCs
    • Including but not limited to:Control Logix
      Compact Logix
      RSLogix
      SLC 500
      PLC5
      MicroLogix
    • Other Class 1 or Class 3 EtherNet/IP PLCs may be supported
  • ISDU Read & WritesUp to 40 individual commands in one EtherNet/IP message
  • ISDU CommandsSelectable byte swapping (none, 16-bit, or 32-bit)
    Selectable payload sizes (4 to 232 bytes)
    ISDU block index
    ISDU sub-index
    Length of read or write
    Data payload
  • Web Page Configuration
    • Provides the following capabilities:Port configuration for ISDU Data, Process Data, Transfer Mode, Read/Write, Write PDI to Tag/File, and Read PDO from Tag/File.
      EtherNet/IP configuration:
      • Time to Live (TTL) Network Value
      • Multicast IP Address Allocation Control
      • User-Defined Number of Multicast IP Addresses
      • User-Defined Multicast Starting IP Address
    • Session Encapsulation Timeout
  • DiagnosticsYes
  • Electronic Data Sheet (EDS)Yes
  • Sample PLC ProgramsYes
Modbus TCP Specifications
  • Supported Controllers (Modbus TCP Masters)PLC
    HMI
    SCADA
    OPC Server
  • Supported ClientsAny Modbus TCP Client
    Applications on phones/tables
  • Web Page ConfigurationPort configuration for ISDU Response Timeout, Process Data, and Transfer Mode.
  • DiagnosticsYes
Additional Features
  • ConfigurationEmbedded web interface, IO-Link, EtherNet/IP, and Modbus TCP
  • Data StorageAutomatic or Manual - Upload and/or Download
  • Device ValidationYes
  • Data ValidationYes
  • DiagnosticsIO-Link, EtherNet/IP, and Modbus TCP
  • Powerful Web Interface
    • Provides the following capabilities:Firmware upgradable
      Password protected with Admin, Operator, and User accounts
      ISDU batch handling
      Load IODD files to configure the IO-Link device
      IODD Handler parses xml files making them readable and configurable
      Save/Load Configuration Files
      Log files
  • Upgradable FirmwareYes (Web page or using PortVision DX)
  • Remote ParameterizationYes
  • Mobile App SupportSimplify monitoring of control system Process and Service Data using simple standard clients available for free in Google Play and Apple App Store
Export Information
  • Packaged Shipping Weight0.9 lbs.
    408 g
  • Package Dimensions (L x W x H)5.7” x 5.7 ” x 3.4”
    145mm x 145mm x 86.4mm
  • UPC Code7-56727-99675-0
  • Country of OriginUSA
  • ECCN5A992
  • Schedule B Number8517.62.0050
Regulatory Approvals
  • ImmunityEuropean Standard EN 61000-6-2
    International Standard IEC 61000-6-2
    • EN/IEC 61131-2 and EN/IEC 61131-9IEC 1000-4-2/EN 61000-4-2: Electrostatic Discharge (ESD)
      IEC 1000-4-3/EN 61000-4-3: Radiated, Radio-Frequency (RF)
      IEC 1000-4-4/EN 61000-4-4: Fast Transient/Burst
      IEC 1000-4-5/EN 61000-4-5: Surge
      IEC 1000-4-6/EN 61000-4-6: Conducted disturbance
      IEC 1000-4-8/EN 61000-4-8: Magnetic field
      IEC 1000-4-11/EN 61000-4-11: Dips and Voltage Variations
  • EmissionEuropean Standard EN 61000-6-4
    International Standard IEC 61000-6-4
    AS/NZS CISPR-11
    • FCC Part15 Subpart B Class A limit
    Canadian EMC requirements ICES-001
  • SafetyCSA C22.2 No. 61010-1-12 / CSA C22.2 No. 61010-1-201
    UL 61010-1 / UL 61010-1-201
    UL File # E360395
  • VibrationEN 60068-2-6/ IEC 60068-2-6
  • Mechanical ShockEN 60068-2-27/ IEC 60068-2-27
  • Environmental / Mechanical Test ApprovalsIEC 61131-2
    IEC 60529
  • Ingress Protection RatingIngress Protection rating IP20 (IEC 60529)
  • OtherThe components of this product comply with the requirements of the EMC/EMI Directive 2014/30/EU, Directive 2011/65/EU on the Restriction of the use of certain Hazardous Substances (RoHS2).
  • Regulatory Approval Symbols

 
Find a Distributor

» Industrial Distributors
» North American Distributors
» International Distributors

Pre-Sales Questions

Pepperl+Fuchs Comtrol's Pre-sales Team
For sales questions or to locate a reseller near you.

+1-800-926-6876 (1-800-Go Rocket)
+1-763-957-6000
Fax: +1-763-957-6001
[email protected]

Pepperl+Fuchs Comtrol's Industrial Automation Sales
For sales questions or to locate an industrial distributor near you.

+1-800-926-6876 (1-800-Go Rocket)
+1-763-957-6000
Fax: +1-763-957-6001
[email protected]


 
Sales Support

Call +1.763.957.6000, or e-mail [email protected]

Technical Support

For technical assistance, our U.S.-based technical support team is only a phone call away.

Call +1.763.957.6000, or submit your question online, or visit our forum .

Software & Documentation
Pepperl+Fuchs Comtrol FTP Site
 
Downloads
File NameDownload
Documentation
Software