IO-Link Master DR-8-EIP

The IO-Link Master DR-8-EIP is an 8-Port IO-Link Master supporting Modbus TCP and EtherNet/IP™ communication, dual Ethernet ports, and screw terminal connections in a compact DIN rail design.

Part Number: 99590-6

PortVision DXweb IIoT


Engineering Drawing

Download Specifications
     
    *View the latest software updates HERE Download our IO-Link Master brochure
     

    IO-Link Master common configuration networking diagram

    IO-Link Master Configuration

    Comtrol's IO-Link Master combines the benefits of the IO-Link standard with the popular industrial Modbus TCP and EtherNet/IP™ protocol by providing a gateway that's a streamlined bridge between the field level sensor network and the industrial Modbus TCP and EtherNet/IP™ backbone, making retrofitting or expansion simple.

    The IO-Link Master easily installs on a standard DIN rail and incorporates two Fast Ethernet ports, eight IO-Link ports, two DI/DO ports and two DI ports. This product is designed with industrial grade components and redundant power inputs to make it exceptionally reliable for critical applications. The IO-Link Master is easily integrated into a system network, and is compatible with existing and new industrial Ethernet environments.

    Learn more about IO-Link

    IO-Link Resources


    Includes:
    • IO-Link Master DR-8-EIP
    • Quick Start card
     
    Hardware
    • Network Interfaces10/100BASE-TX
    • EnclosurePolyamide
    • Ingress Protection RatingIP20
    • Installation and Grounding MethodDIN rail
    • Network ProtocolsEtherNet/IP™, Modbus/TCP (slave)
    • ConnectorsDI/DO, Ethernet, IO-Link, Power
    • LED IndicatorsPower, Module Status, Network Status, IO-Link, DI, DIO States, and Ethernet Port Status
    • Dimensions (L x W x H) 3.9" x 4.5" x 1.8"
      100 x 115 x 45 mm
    • Product Weight10 oz
      285 g
    IO-Link Interface Specifications
    • Connector TypeScrew terminal
    • Number of Ports8
    • IO-Link VersionSupports V1.0 and V1.1
    • Terminal Pinout
    • Configurations Per PortIO-Link, or DI or DO on Pin 4
      DI (dedicated) on Pin 2
    • IO-Link Mode Transfer Rates4.8K (COM1)
      38.4K (COM2)
      230.4K (COM3)
    • Baud rate recognitionAutomatic
    • Maximum Output Current on IO-Link Connectors (Ports 1-8)
      • Vs on Pins 1, 3200mA
      • C/Q on Pin 4200mA
    • Overload ProtectionYes - Vs on Pins 1, 3 and C/Q on Pin 4
    • Short Circuit ProtectionYes - C/Q on Pin 4
    • Cable Length (Max.)20m
    Digital Inputs C/Q (SIO Mode Using IO-Link Ports)
    • Sensor Current Load (Maximum)200mA
    • Input CharacteristicsIEC 61131-2 Type 1 and Type 3 Compliant
    • Short-Circuit and Overload protectionYes
    • Short-Circuit proofYes
    • Input Current LimitationYes
    • C/Q Input ThresholdLow: 8.0 - 11.5V
      High: 10.5 - 13.0V
    • Cable Length (Max.)30m
    Digital Outputs C/Q (SIO Mode Using IO-Link Ports)
    • Actuator Current Load (Maximum)200mA
    • Input CharacteristicsIEC 61131-2 Type 1 and Type 3 Compliant
    • Short-Circuit and Overload protectionYes
    • Short-Circuit proofYes
    • Input Current LimitationYes
    • Output FunctionPNP/NPN
    • Cable Length (Max.)30m
    Digital Inputs C/Q (DI and DIO Pin)
    • Sensor Current Load (Maximum)200mA
    • Input CharacteristicsIEC 61131-2 Type 1 and Type 3 Compliant
    • Short-Circuit and Overload protectionYes
    • Short-Circuit proofYes
    • Input Current LimitationYes
    • C/Q Input ThresholdLow: 5.2 - 6.4V
      High: 6.8 - 8.0V
    • Cable Length (Max.)30m
    Digital Output C/Q Pin (SIO Mode Using IO-Link Ports)
    • Actuator Current Load (Maximum)200mA
    • Short-Circuit and Overload protectionYes
    • Short-Circuit proofYes
    • Input Current LimitationYes
    • Output FunctionPNP/NPN
    • Cable Length (Max.)30m
    Digital Input C/Q (DI and DIO Pin)
    • Sensor Current Load (Maximum)200mA
    • Input CharacteristicsIEC 61131-2 Type 1 and Type 3 Compliant
    • Short-Circuit and Overload protectionYes
    • Short-Circuit proofYes
    • Input Current LimitationYes
    • C/Q Input ThresholdLow: 5.2 - 6.4V
      High: 6.8 - 8.0V
    • Cable Length (Max.)30m
    Digital Outputs DIO Pin
    • Actuator Current Load (Maximum)200mA
    • Short-Circuit and Overload protectionYes
    • Short-Circuit proofYes
    • Input Current LimitationYes
    • Output FunctionPNP/NPN
    • Cable length (maximum)30m
    Dedicated Digital IO Ports (Digital Input Mode)
    • Connector TypeScrew Terminal
    • Number of Ports2 (D1 & D3)
    • Cable Length (Max.)30m
    Digital Inputs/Outputs
    • Connector TypeScrew Terminal
    • Number of Ports2 (D2 & D4)
    • Configurations per portDI/DO (configurable) = 1
      DI (dedicated) = 1
    • Cable Length (Max.)30m
    Digital Outputs
    • Actuator (Sensor) Current Load (Maximum)200mA
    • Lamp Load (Maximum)4W
    • Over Load and Short Circuit ProtectionYes
    • Switching OutputPNP, NPN
    Ethernet Interface Specifications
    • Connector TypeRJ45
    • Number of Ports2
    • Ethernet Specification 10/100BASE-TX
    • StandardsIEEE 802.3: 10BASE-T
      IEEE 802.3u: 100BASE-TX
    • Auto-MD/MDI-XYes
    • Auto-NegotiationYes
    • Link Distance100 m
    • Cable TypesUnshielded or Shielded twisted pair
    • IPv4 AddressingYes
    Ethernet/IP Interface Specifications
    • Supported PLCsIncluding but not limited to:
      • Control Logix
      • Compact Logix
      • RSLogix
      • SLC 500
      • PLC5
      • MicroLogix
      • Other Class 1 or Class 3 EtherNet/IP PLCs may be supported
    • ISDU Read & WritesUp to 40 individual commands in one EtherNet/IP message
    • ISDU CommandsSelectable byte swapping (none, 16-bit, or 32-bit)
      Selectable payload sizes (4 to 232 bytes)
      ISDU block index
      ISDU sub-index
      Length of read or write
      Data payload
    • Web Page ConfigurationProvides the following capabilities:
      • Port configuration for ISDU Data, Process Data, Transfer Mode, Read/Write, Write PDI to Tag/File, and Read PDO from Tag/File.
      • EtherNet/IP configuration:
      • Time to Live (TTL) Network Value
      • Multicast IP Address Allocation Control
      • User-Defined Number of Multicast IP Addresses
      • User-Defined Multicast Starting IP Address
      • Session Encapsulation Timeout
    • DiagnosticsYes
    • Electronic Data Sheets (EDS)Yes
    • Sample PLC ProgramsYes
    Modbus TCP Interface
    • Supported Controllers (Modbus TCP Masters)PLC
      HMI
      SCADA
      OPC Server
    • Supported ClientsAny Modbus TCP Client
      Applications on phones/tables
    • Web Page ConfigurationPort configuration for ISDU Response Timeout, Process Data, and Transfer Mode
    • DiagnosticsYes
    DR-8-EIP Features
    • Data StorageAutomatic or Manual - Upload and/or Download
    • Device ValidationYes
    • Data ValidationYes
    • Powerful Web InterfaceProvides the following capabilites:
      • Firmware upgradable
      • Password protected with Admin, Operator, and User accounts
      • ISDU batch handling
      • Load IODD files to configure the IO-Link device
      • IODD Handler parses xml files making them readable and configurable
      • Log files
    • Upgradable FirmwareYes (Web page or using PortVision DX)
    • Remote ParameterizationYes
    • Mobile App SupportSimplify monitoring of control system Process and Service Data using simple standard clients available for free in Google Play and Apple App Store
    Electrical Specifications
    • DC Input Voltage Range18-30VDC
    • Current Consumption (Max.) 4.3A @ 24VDC
    • Current Consumption (w/out devices)100mA
    • Current Consumption (with load)4.04A
    • Power Consumption (w/out load)2.4W
    • Power Connectors (2)Screw Terminals
    Environmental Specifications
    • Air Temperature
      • System On -40°C to +70°C
      • System Off -40°C to +70°C
    • Operating Humidity (non-condensing)10% to 95%
    • Storage Humidity (non-condensing)10% to 95%
    • Shock/VibrationsEN60068-2-6
      EN60068-2-27
    Export Information
    • Package Weight1.1 lbs
      481.94 g
    • Package Dimensions9.2” x 7.25” x 2.5”
      233 x 184 x 64 mm
    • UPC Code7-56727-99590-6
    • Country of OriginUSA
    • ECCN5A992
    • Schedule B Number8517.62.0050
    • Regulatory Approvals
      • ImmunityEuropean Standard 61000-6-2
        International Standard IEC 61000-6-2
        IEC 61131-2
        IEC 1000-4-2/EN 61000-4-2: Electrostatic Discharge (ESD)
        IEC 1000-4-3/EN 61000-4-3: Radiated, Radio-Frequency (RF)
        IEC 1000-4-4 /EN 61000-4-4: Fast Transient/Burst
        IEC 1000-4-5/EN 61000-4-5: Surge
        IEC 1000-4-6/EN 61000-4-6: Conducted disturbance
        IEC 1000-4-8/EN 61000-4-8: Magnetic Field
        IEC 1000-4-11/EN 61000-4-11: Dips and Voltage Variations
      • EmissionsEuropean Standard EN 61000-6-4
        International Standard IEC 61000-6-4
        AS/NZS CISPR-11
        FCC Part15 Subpart B: Class A limit
        Canadian EMC requirements ICES-001
      • SafetyCSA C22.2 No. 61010-1-12 / CSA C22.2 No. 61010-1-201
        UL 61010-1/UL 61010-1-201
      • OtherIngress Protection rating [email protected]) (IEC 60529)
        Environmental & Mechanical testing pre IEC/EN 61131-2
        European Standard: 2011/65/EU (RoHS2) Directive.
      • Regulatory Approval Symbols
     
    Find a Distributor

    » Industrial Distributors
    » North American Distributors
    » International Distributors

    Pre-Sales Questions

    Comtrol's Pre-sales Team
    For sales questions or to locate a reseller near you.

    +1-800-926-6876 (1-800-Go Rocket)
    +1-763-957-6000
    Fax: +1-763-957-6001
    [email protected]

    Comtrol's Industrial Automation Sales
    For sales questions or to locate an industrial distributor near you.

    +1-800-926-6876 (1-800-Go Rocket)
    +1-763-957-6000
    Fax: +1-763-957-6001
    [email protected]


     
    Documentation
    DocumentDescriptionDownload File
    IO-Link Master DR-8-EIP User GuideContains detailed installation procedures and configuration information.
    Product Support and Service Information
    Sales Support

    Call +1.763.957.6000, or e-mail [email protected]

    Technical Support

    For technical assistance, our U.S.-based technical support team is only a phone call away.

    Call +1.763.957.6000, or submit your question online, or visit our forum .

    Software and Documentation
    Comtrol FTP Site