IO-Link Master 4-EIP

The IO-Link Master supports Modbus TCP and EtherNet/IP and features rugged housing with M12 connectors for harsh environments. This industrial IO-Link gateway has a wide operating temperature from 0° to 55°C.

Part Number: 99570-8

PortVision DXweb IIoT


Engineering Drawing

Download Specifications
     
      *View the latest software updates HERE Download our IO-Link Master brochure housing with dimensionsBACK TO IO-Link Features
     

    IO-Link Master common configuration networking diagram

    IO-Link Master Configuration

    Comtrol’s IO-Link Master combines the benefits of the IO-Link standard with the Modbus TCP and EtherNet/IP™ protocols. The IO-Link Master effectively shields the PLC programmers from the IO-Link complexities by handling those complexities itself. The result is simplified Modbus TCP and EtherNet/IP™ interfaces,which decreases system development time and installation efforts.

    The IO-Link Master features a rugged IP67 slim-line design incorporating two Fast Ethernet ports and four IO-Link ports with M12 connectors. Designed for harsh environments, its machine-mount design uses industrial grade components. The IO-Link Master is easily integrated into a system network, and is compatible with existing and new industrial Ethernet installations.

    Learn more about IO-Link

    IO-Link Resources


    Includes:
    • IO-Link Master 4-EIP
    • Quick Start card
    • M12 connector caps
     
    Hardware
    • Network Interface 10/100BASE-TX
    • EnclosureMolded ABS (potted)
    • Ingress Protection Rating IP67
    • Installation and Grounding MethodMachine or panel mount
      Two-hole M4 or #8 screws
    • Network ProtocolsEtherNet/IP™, Modbus/TCP (slave)
    • Connectors (M12)4 - IO-Link
      2 - Ethernet
      2 - Power
    • LED IndicatorsPower, Module Status, Network Status, IO-Link, DI and Ethernet Port Link/Activity Status
    • Dimensions 6.07" x 2.04" x 1.68"
      154 x 51.8 x 42.7 mm
    • Product Weight 0.70 lb
      318g
    IO-Link Interface Specifications
    • Connector TypeFemale, M12, A-coded, 5-pin
    • Number of Ports4
    • IO-Link Version Supports V1.0 and V1.1
    • Connector Pinout Pin 1 = L+
      Pin 2 = DI
      Pin 3 = L-
      Pin 4 = C/Q
      Pin 5 = Not Connected
    • Configurations per Port IO-Link or DI or DO on Pin 4
      DI (dedicated) on Pin 2
    • IO-Link Mode Transfer Rates4.8K (COM1)
      38.4K (COM2)
      230.4K (COM3)
    • Baud Rate RecognitionAutomatic
    • Maximum Output Current on IO-Link Connectors (Ports 1-4)* Starting with serial number: 9570-000626
      • Vs on Pins 1, 3500mA* (Maximum)
      • C/Q on Pin 4200mA (Maximum)
    • Overload ProtectionYes - Vs on Pins on 1, 3 and C/Q on Pin 4
    • Short Circuit ProtectionYes - C/Q on Pin 4
    • Cable Length (Maximum)20 m
    Digital Inputs C/Q (SIO Mode Using IO-Link Ports)
    • Sensor Current Load (Maximum)200mA
    • Input CharacteristicsIEC 61131-2 Type 1 and Type 3 Compliant
    • Input Current LimitationYes
    • C/Q Input ThresholdLow: 8.0 - 11.5V
      High: 10.5 - 13.0V
    • Cable Length (Maximum)30 m
    Digital Outputs C/Q (SIO Mode Using IO-Link Ports)
    • Actuator Current Load (Maximum)200mA
    • Input CharacteristicsIEC 61131-2 Type 1 and Type 3 Compliant
    • Short-Circuit and Overload ProtectionYes
    • Short-Circuit ProofYes
    • Output FunctionPNP/NPN
    • Cable Length (Maximum)30 m
    Digital Input (Only) Specifications
    • Actuator Current Load (Maximum)200mA
    • Input CharacteristicsIEC 61131-2 Type 1 and Type 3 Compliant
    • Input Current LimitationYes
    • DI Input ThresholdLow: 5.2 - 6.4V
      High: 6.8 - 8.0V
    • Voltage Limit-40 to + 40VDC
    • Cable Length (Maximum)30 m
    Ethernet Interface Specifications
    • Connector TypeFemale, M12 D-coded, 4-pin
    • Number of Ports2
    • Ethernet Specification10/100BASE-TX
    • StandardsIEEE 802.3: 10BASE-T
      IEEE 802.3u: 100BASE-TX
    • Auto-MDI/MDI-XYes
    • Auto-NegotiationYes
    • Link Distance100 m
    • Cables TypesTwisted pair (Cat 5 or higher)
    • IPv4 AddressingYes
    Ethernet/IP Interface Specifications
    • Supported PLCsIncluding but not limited to:
      • Control Logix
      • Compact Logix
      • RSLogix
      • SLC 500
      • PLC5
      • MicroLogix
      • Other Class 1 or Class 3 EtherNet/IP PLCs may be supported
    • ISDU Read & WritesUp to 40 individual commands in one EtherNet/IP message
    • ISDU CommandsSelectable byte swapping (none, 16-bit, or 32-bit)
      Selectable payload sizes (4 to 232 bytes)
      ISDU block index
      ISDU sub-index
      Length of read or write
      Data payload
    • Web Page ConfigurationProvides the following capabilities:
      • Port configuration for ISDU Data, Process Data, Transfer Mode, Read/Write, Write PDI to Tag/File, and Read PDO from Tag/File.
      • EtherNet/IP configuration:
           • Time to Live (TTL) Network Value
           • Multicast IP Address Allocation Control
           • User-Defined Number of Multicast IP Addresses
           • User-Defined Multicast Starting IP Address
           • Session Encapsulation Timeout
    • DiagnosticsYes
    • Electronic Data Sheets (EDS)Yes
    • Sample PLC ProgramsYes
    Modbus TCP Interface
    • Supported Controllers (Modbus TCP Masters)PLC
      HMI
      SCADA
      OPC Server
    • Supported ClientsAny Modbus TCP Client
      Applications on phones/tables
    • Web Page ConfigurationPort configuration for ISDU Response Timeout, Process Data, and Transfer Mode
    • DiagnosticsYes
    4-EIP Features
    • Data StorageAutomatic or Manual - Upload and/or Download
    • Device ValidationYes
    • Data ValidationYes
    • Powerful Web InterfaceProvides the following capabilites:
      • Firmware upgradable
      • Password protected with Admin, Operator, and User accounts
      • ISDU batch handling
      • Load IODD files to configure the IO-Link device
      • IODD Handler parses xml files making them readable and configurable
      • Log files
    • Upgradable FirmwareYes (Web page or using PortVision DX)
    • Remote ParameterizationYes
    Electrical Specifications
    • Input Voltage Rance20-30VDC / 4A (Maximum)
    • Power Supply In (Us)4A (Maximum)
    • Power Consuption (Without Load)100mA @ 24VDC (Vs)
    • Power Supply Out (Us) *Us output available is determined by subtracting the following from the available input current:
      • • IO-Link module power
      • • Actual C/Q current for each IO-Link port (w/out devices)4A (Maximum*)
      • • Actual Vs current for each IO-Link port
    • Power Connectors
      • Input (1)Male, M12 A-coded, 5-pin
      • Output (2)Female, M12 A-coded, 5-pin
    Environmental Specifications
    • Air Temperature
      • System On 0°C to +55°C*
      • System Off -40°C to +70°C*
    • Operating Humidity (non-condensing)10% to 95%
    • Storage Humidity (non-condensing)10% to 95%
    • Shock/VibrationsEN60068-2-6
      EN60068-2-27
    • Enclosure RatingIP67 (IEC 60529)
    Export Information
    • Packaged Shipping Weight1.05 lb
      455g
    • Package Dimensions (L x W x H)9.19" x 7.25" x 2.5"
      233 x 184 x 63.5mm
    • UPC Code7-56727-99570-8
    • Country of OriginUSA
    • ECCN5A992
    • Schedule B Number8517.62.0050
    Regulatory Approvals
    • ImmunityEuropean Standard EN 61000-6-2
      IEC/EN 61131-2
      IEC 1000-4-2/EN 61000-4-2: Electrostatic Discharge (ESD)
      IEC 1000-4-3/EN 61000-4-3: Radiated, Radio-Frequency (RF)
      IEC 1000-4-4/EN 61000-4-4: Fast Transient/Burst
      IEC 1000-4-5/EN 61000-4-5: Surge
      IEC 1000-4-6/EN 61000-4-6: Conducted disturbance
      IEC 1000-4-8/EN 61000-4-8: Magnetic field
      IEC 1000-4-11/EN 61000-4-11: Dips and Voltage Variations
    • EmissionsEuropean Standard EN 61000-6-4
      AS/NZS CISPR-22
      FCC Part15 Subpart B
      Class A limit
      Canadian EMC requirements ICES-003
    • SafetyCSA C22.2 No. 142/UL 508E360395
    • OtherIngress Protection rating IP67 (IEC 60529)
      Environmental & Mechanical testing pre IEC/EN 61131-2
      Europeal Standard: 2011/65/EU (RoHS2) Directive.
    • Regulatory Approval Symbols
     
    Find a Distributor

    » Industrial Distributors
    » North American Distributors
    » International Distributors

    Pre-Sales Questions

    Comtrol's Pre-sales Team
    For sales questions or to locate a reseller near you.

    +1-800-926-6876 (1-800-Go Rocket)
    +1-763-957-6000
    Fax: +1-763-957-6001
    [email protected]

    Comtrol's Industrial Automation Sales
    For sales questions or to locate an industrial distributor near you.

    +1-800-926-6876 (1-800-Go Rocket)
    +1-763-957-6000
    Fax: +1-763-957-6001
    [email protected]


     
    Documentation
    DocumentDescriptionDownload File
    IO-Link Master 4-EIP User GuideContains detailed installation procedures and configuration information.
    Product Support and Service Information
    Sales Support

    Call +1.763.957.6000, or e-mail [email protected]

    Technical Support

    For technical assistance, our U.S.-based technical support team is only a phone call away.

    Call +1.763.957.6000, or submit your question online, or visit our forum .

    Software & Drivers
    » Comtrol FTP Site
     
    Downloads
    File NameDownload
    Documentation
    Software