  • DIN rail mounting and screw terminal power connections
  • Highly flexible and unique Modbus functionality
  • Surge protection for serial ports
  • Multiple Modbus master and slave types
  • Raw/ASCII Serial and Ethernet device support
  • Variable power input eliminates need for power converters
  • Dual Ethernet ports for daisy chaining network connections between multiple units
  • RoHS 2 compliant under CE

View the DeviceMaster UP Modbus Solutions

 

The DeviceMaster MOD has been designed to meet the demands of today’s increasingly diverse Modbus installations.

Pepperl+Fuchs Comtrol has developed three unique Modbus firmware applications that provide a wide range of Modbus connectivity. Simple connections or complex Modbus networks, you can do it all with a DeviceMaster MOD.

Highly flexible and robust, the DeviceMaster MOD provides connectivity between a vast array of Modbus controllers and devices. Simplified configuration pages, innovative functionality and informative diagnostic information all make for quick and easy set-up of even the most complex Modbus installations.


Includes:
  • DeviceMaster MOD-2302
  • Loopback Plug
  • Quick Installation Guide
 
Hardware
  • Bus Interface Specification 10/100 BASE-T
  • Memory
    • SDRAM 32 MB
    • Flash 8 MB
  • Enclosure UL94-V0 PLASTIC
  • Installation Method DIN Rail (35mm)
  • LED Indicators ETHERNET ACTIVITY, ETHERNET LINK, and STATUS
  • Dimensions 4.6" x 3.9" x 1.8"
    11.68 x 9.9 x 4.57 cm
  • Product Weight 6.5 oz
    184.27 g
Electrical Specifications
  • DC Input Voltage 6-30V
  • Device
    • Current Consumption +24VDC 85 mA
    • Power Consumption (maximum) 2.0 W
  • Power Input Redundancy Dual Redundant Power Input
  • ESD Surge Protection Provided minimum of 25KV protection for all serial lines. All Ethernet components are rated to 1.5KV magnetic surge protection.
Environmental Specifications
  • Air temperature
    • System On -37 to 74° C
    • System Off -40 to 85° C
  • Operating Humidity (non-condensing) 5% to 95%
  • Altitude 0 to 10,000 Feet
    3,048 m
  • Heat Output 6.8 BTU/Hr
  • MTBF (Mean Time Between Failures) 49.5 Years

Serial Communications

  • Connector Type DB9 Male
  • Number of Ports 2
  • Software Interfaces RS-232
    RS-422
    RS-485 2-Wire
    RS-485 4-Wire (Master/Slave)
  • Baud Rate 300 to 230.4Kbps
    • Receive Buffer 1024bytes
    • Transmit Buffer 256bytes
  • Serial Data Control
    • Data Bits5, 6, 7 or 8
    • Parityodd, even, or none
    • Stop Bits 1, 1.5, or 2
    • Flow Control None, RTS/CTS, XON/XOFF, or Half-duplex
  • *Stop bit 1.5: Supported only when used with 5 data bits

Communication Modes

    • Modbus TCP/RTU/ASCII to raw/ASCII Serial or Ethernet TCP/IP
    • Modbus/TCP to Modbus RTU/ASCII
    • Modbus RTU/ASCII (Auto Locate and Auto Route)
    • Raw/ASCII Data Stream and Command/Response Modes
    • Remote Modbus TCP/RTU/ASCII
Ethernet Specifications
  • Network Protocols ARP, BOOTP, DHCP, HTTP, ICMP, Ping, RARP, RFC 1006 (ISO over TCP), RFC 2217, SNMP (MIB-II), TCP/IP, Telnet, TFTP, and UDP socket services
  • Connector TypeRJ45F Auto MDI/MDI-X
Modbus Router Features (Default)
  • DescriptionPure Modbus, multiple Modbus master and slave types , remote, local, and private devices
  • Supported InterfacesPLCs, SCADA systems, HMIs, OPC servers and applications
  • Web Page Configuration• Master-to-master connectivity via the Shared Memory sub-system
    • Private Modbus serial bus support designed to restrict access to private Modbus devices
    • Connectivity from serial Modbus masters to Modbus/TCP networks
    • The ability to connect multiple types of Modbus masters to Modbus slave device(s)
    • Convert from one form of Modbus, such as Modbus/TCP, to Modbus/RTU or Modbus/ASCII
    • Provide connectivity from a serial Modbus master to a remote Modbus slave device
    • Eliminate Modbus device ID conflicts and solve device ID configuration problems
    • Enable Modbus security by blocking write messages in Read-Only Mode
    • Device ID to Modbus/TCP slave via configurable IP address and TCP/IP port
    • Modbus Network Bridging support
  • DiagnosticsLocal and remote slave device and port specific diagnostic web pages that display status, message response timing, timeout and other error counts, and overall message statistics. A serial log is also included to provide message level diagnosis.
Modbus Server Features (Downloadable)
  • DescriptionModbus/RTU over Ethernet master(s) to serial slave(s)
  • Supported InterfacesOPC Servers and Applications that require Modbus/RTU communication over Com ports or Ethernet TCP/IP connections
  • Web Page Configuration• Supports Modbus/RTU over Ethernet TCP/IP connections to the corresponding serial port via intelligent Modbus message handling and routing.
    • Supports only Modbus/RTU over Ethernet TCP/IP connections to a serial port. For Modbus/TCP functionality, please see the DeviceMaster UP.
    • Supports up to six Ethernet TCP/IP connections to each serial port.
    • Supports up to 255 Modbus devices per port. Both valid, (1-247), and reserved, (248-255), device ids are supported
    • Modbus/RTU specific message handling: ◦CRC verification of all messages received on the TCP/IP and serial interfaces
    • Timing out of responses from slave Modbus/RTU devices
    • Broadcast message handling on connected port only
    • System monitoring to ensure gateway operation:
    • Gateway busy
    • Application message timeouts
    • Combined with a serial port redirector, such as the Comtrol Secure Port Redirector, can support up to six COM port connections to each serial port
  • Diagnostics• Modbus device specific statistics, response timing, and status. Up to 255 devices per serial port can be monitored simultaneously.
    • Serial port specific statistics and status
    • Serial port message logging
Modbus/TCP Features (Downloadable)
  • Supported InterfacesPLC, SCADA system, HMI, or OPC Server
  • Supported Controllers• Modbus/TCP masters and slaves
    • Modbus/RTU and Modbus/ASCII serial masters and slaves
    • Applications over Ethernet TCP/IP connections (raw/ASCII only)
  • Supported Devices• Raw/ASCII devices, both serial and Ethernet TCP/IP, such as barcode scanners, vision systems, RFID readers, weigh scales, encoders and printers
    • Modbus/RTU and Modbus/ASCII serial slaves
  • Recommended Installations• Connectivity to serial and/or Ethernet TCP/IP raw/ASCII devices
    • Connectivity to Modbus/RTU and/or Modbus/ASCII serial devices
    • Connecting single or multiple Modbus masters and/or applications to the devices
    • Automatic Modbus protocol translations (if needed)
  • Web Page Configuration• Highly flexible, with an emphasis on Raw/ASCII devices
    • Also supports Modbus RTU/ASCII slave devices
    • Connect Raw/ASCII devices to Modbus/TCP and Modbus RTU/ASCII serial controllers
    • Automatic protocol conversions and routing
    • Connect Modbus/TCP and Modbus RTU/ASCII serial masters to Modbus RTU/ASCII serial slaves
    • Many unique Raw/ASCII handling features
    • Simultaneously connect multiple Modbus masters to individual devices
    • Modbus message Alias Device ID conversions
  • DiagnosticsYes
  • Sample PLC ProgramsYes
Export Information
  • Packaged Shipping Weight 1.1 lbs
    0.5 kg
  • Package Dimensions9.25" x 2.5" x 7.25"
    "23.5 x 6.35 x 18.42 cm
  • UPC Code 7-56727-99562-3
  • Country of Origin USA
  • ECCN 5A992
  • Schedule B Number 8471.80.1000
Regulatory Approvals
  • Emissions FCC Part 15 Subpart B: Class A limit
    AS/NZS CISPR-22
    European Standard EN55022
    Canadian EMC requirements
    ICES-003
  • Immunity European Standard EN55024
    IEC 1000-4-2/EN61000-4-2: ESD
    IEC 1000-4-3/EN61000-4-3: RF
    IEC 1000-4-4/EN61000-4-4: Fast Transient
    IEC 1000-4-5/EN61000-4-5: Surge
    IEC 1000-4-6/EN61000-4-6: Conducted Disturbance
    IEC 1000-4-8/EN61000-4-8: Magnetic Field
    IEC 1000-4-11/EN61000-4-11: Dips and Voltage Variations
  • Safety IEC 60950/EN60950 (RECOGNIZED)
    CSA C22.2 No. 60950/UL60950
  • Other Regulatory Approvals European Standard: RoHS 2 Compliant under CE
    NEMA TS2 COMPLIANT

Pinout Diagram
  • Ground must be tied to signal ground.Pinout Diagrams
 
Find a Distributor

» Industrial Distributors
» North American Distributors
» International Distributors

Pre-Sales Questions

Pepperl+Fuchs Comtrol's Pre-sales Team
For sales questions or to locate a reseller near you.

+1-800-926-6876 (1-800-Go Rocket)
+1-763-957-6000
Fax: +1-763-957-6001
[email protected]

Pepperl+Fuchs Comtrol's Industrial Automation Sales
For sales questions or to locate an industrial distributor near you.

+1-800-926-6876 (1-800-Go Rocket)
+1-763-957-6000
Fax: +1-763-957-6001
[email protected]


 
Product Support and Service Information

Part Number: 99562-3

Sales Support

Call +1.763.957.6000, or e-mail [email protected]

Technical Support

For technical assistance, our U.S.-based technical support team is only a phone call away.

Call +1.763.957.6000, or visit our forum .

Warranty

Pepperl+Fuchs Comtrol offers a 30-Day satisfaction guarantee and a 5-year limited warranty on all DeviceMaster products! View Warranty

Extended Warranty Available

Software & Drivers
» Comtrol FTP Site